Manual
Operation 4-11
Table 4-4 Motion Control Functions
Button/Indicator Function
Z AXIS
Z-Axis Controls (up/down)
§ Click and release a single arrow to move
dispensing head 1 mm (0.001 inches)
§ Click and hold single arrow to move dispensing
head 25.4 mm per second (1 in/sec)
§ Click and hold double arrow to move dispensing
head 50-75 mm per second (2-3 in/sec)
TEACH
TEACH lets you set a desired point on the dispensing
surface with the Fluidmove program. The location of the
fiducial is stored by the software.
FIND
HOME
FIND HOME sends the dispensing head to either its XYZ
or its Z machine origin, also called “home.”
Before you press FIND HOME, verify that the
DISPENSER button’s LED is lit, indicating its controls are
active.
FIND HOME can be used in two ways:
1. To move the dispense head to XYZ machine origin
and re-establish its “Home” reference coordinates,
press FIND HOME. The dispensing head finds home
in the following order:
a. Finds the Z-Axis Home first (up/down position)
b. Moves in the Y-Axis at 50-75 mm/sec (2-3 in/sec)
to the front of the dispensing area
c. Moves in the X-Axis at 50-75 mm/sec (2-3 in/sec)
to the front left corner of the dispensing area
2. To move the dispense head to its Z machine origin
and re-establish its “Home” reference coordinates,
first press a “Z” axis UP button, then press FIND
HOME.