Manual
4-10 Operation
Control Panel
The Control Panel is divided into three functional areas:
• Download Program Controls
• Motion Controls
• Dispensing Status/Safety Interlock Controls
The following tables describe each Control Panel function.
Table 4-3 Download Program Control Functions
Button/Indicator Function
ABORT
ABORT halts a production run. After you press the
ABORT button, its red LED lights to indicate that the
currently loaded program is discontinued. After a
program is aborted you must press RESET, then
FIND HOME before you can restart the program.
PAUSE
PAUSE temporarily stops a production run. When its
yellow LED indicator is ON, the system is paused. You
can pause a production run at any time. To resume
dispensing, press PAUSE again. When the LED
indicator turns OFF, the system resumes dispensing.
PROGRAM
0
1
2
3
4
5
6
7
8
9
START
Download Program Controls. The LED indicators
numbered 0-9 indicate dispensing programs that are
saved in the dispensing system memory. Use the
up/down arrows to select the desired dispensing
program. Press START to run the selected program.