Manual
Height Sensor 10-5
Setup
Before performing any dispensing programs with the Height Sensor, make sure that the
Height Sensor is properly set up. To set up the Height Sensor, follow the instructions
below.
Hardware Setup
Once you have installed your Height Sensor, perform the following hardware setup
procedure to verify that the Height Sensor is in a neutral position before making any probe
adjustments or performing the software setup procedure.
?
NOTE
The following procedure may be performed either by an operator
or by a service technician.
To setup the Height Sensor:
1. Check the location of the Micrometer Locking Screw (see Figure 10-1).
2. The screw should be centered in the slot on the bracket. If the screw is already centered
in the slot, the hardware setup is complete. Stop here. If the screw is not centered in the
slot, continue with the next step.
3. Loosen the Micrometer Locking Screw.
4. Adjust the Micrometer Adjustment until the Micrometer Locking Screw is centered in
the slot.
> After centering the screw, it is recommended that you adjust the Micrometer
Adjustment to “0” as a starting point for any future probe adjustments.
5. Tighten the Micrometer Locking Screw.
End of Procedure