Manual
10-2 Height Sensor
Installation
See Figure 10-2 to locate parts.
Tools and Materials Needed
• Height Sensor
• Philips head screwdriver
CAUTION!
Only a trained service technician should perform this procedure.
To install the Height Sensor:
1. Determine the type of valve or fluid pump installed on your dispensing system.
?
NOTE
DV-6000 pumps, DP Series pumps, and the DJ-2000 DispenseJet
®
attach directly to the valve bracket (see Figure 10-2). Go to Step 3.
?
NOTE
DV-01, DV-02, DV-03, DV-05, DV-07, DV-08, and DV-09
valves require a Bracket Spacer (P/N 03-0266-25) when installing
the Height Sensor. The bracket spacer fits between the Z-head and
the height sensor (see Figure 10-3).
2. Using the Philips head screwdriver, secure the bracket spacer to the Z-head with the
screws included with the Height Sensor.
3. Align the Height Sensor to the screw holes on the right side of the valve bracket or
bracket spacer.
4. Using the Philips head screwdriver, secure the Height Sensor to the valve bracket or
bracket spacer with the screws included with the Height Sensor.
> On some valves or fluid pumps, the top screw may not be needed to secure the
Height Sensor.
5. With the system turned OFF, plug the Height Sensor Power Cord into the Height
Sensor connector on the back of the dispensing head.
End of Procedure