User guide
10-2 Height Senso
r
To install the HS-Series Height Sensor:
1. Determine the type of valve or fluid pump installed on your dispensing system.
?
NOTE DV-6000 pumps, DV-7000 pumps, DP-Series pumps, and the DJ-2100 DispenseJet
attach directly to the valve bracket (see Figure 10-3). Go to Step 3.
?
NOTE DV-01, DV-02, DV-03, DV-05, DV-07, DV-08, and DV-09 valves require a bracket
spacer when installing the Height Sensor. The bracket spacer fits between the Z-head and
the height sensor (see Figure 10-4). Go to Step 2.
?
NOTE If your dispensing system is equipped with a DP-3000 Series pump, see the DP-3000
Series Linear Dispensing Pump Installation and Operation Manual for Height Sensor
installation instructions.
2. Using the Philips head screwdriver, secure the bracket spacer to the Z-head with the screws
included with the Height Sensor.
3. Align the Height Sensor to the screw holes on the right side of the valve bracket or bracket
spacer.
4. Using the Philips head screwdriver, secure the Height Sensor to the valve bracket or bracket
spacer with the screws included with the Height Sensor.
> On some valves or fluid pumps, the top screw is not needed to secure the Height Sensor.
5. Plug the Height Sensor Power Cord into the Height Sensor power connector on the Dispensing
Head.
> The Height Sensor power connector is on the backside of the Dispensing Head.