Maintenance 7-3
Emptying the Water Trap
Moisture from the outside air can condense in the pneumatic system. The water trap collects this
condensed water, and you must empty it periodically, or whenever it is full.
WARNING! Do not remove the steel bowl guard protecting the water trap. The bowl is
made of polycarbonate plastic, which could rupture if the inside or outside
of the bowl is exposed to chemicals incompatible with polycarbonate.
To empty the water trap:
1. Locate the water trap at the rear of the system.
2. Disconnect the facility air supply from the Main Air Inlet.
3. Hold a container under the water trap to catch the water.
4. Using your finger, push the water drain knob at the bottom.
5. Reconnect the facility air supply to the Main Air Inlet.
Item Description
1 Bowl Guard
2 Drain Button (push up to drain)
3 Pneumatic Line to Facility Air
4 Main Air Inlet
Figure 7-1 Water Trap
1
2
3
4