User guide
4-20 Operation
Fluid Pressure
The fluid pressure regulator controls the pressure of air from the Main Air Inlet to the clear pneumatic
fitting located on the right side of the Dispensing Head. This fitting connects to the top of the syringe.
The system maintains steady fluid pressure by applying air at a constant pressure to the syringe while the
dispensing system is ON. For more details on how air pressure is used for fluid pump or valve operation,
see the manual for your specific fluid pump.
Consult the fluid pump installation and operation manual for the recommended setting for your fluid
pump.
Item Description
1
Fluid 2 Pressure Digital Gauge
2
Fluid Pressure Digital Gauge
3 Fluid Pressure Regulator
4 Fluid 2 Pressure Regulator
Figure 4-6 Fluid Pressure Gauges and Regulators
3
4
1
2