User guide

3-10 Safety
Table 3-3 Beacon Color Indications
Panel / Beacon
Color
Dispensing Status Recovery Procedures
RED
(Audible Alarm)
ALERT
All motion, outputs, fluid pump, and
motion controls are disabled.
One of the following conditions exists:
A. Not Flashing – system in an
E-stop condition.
B. Not Flashing – Software driven
error message displayed on
computer monitor
C. Custom-programmed condition
has triggered red light.
A.
1. Remedy anomaly causing
the E-stop.
2. Reset EMO button.
3. Perform an operator startup
as specified in
Startup/Shutdown section.
B. Respond to error message.
Refer to Fluidmove for Windows
NT User Guide
C. See custom-programmed
condition recovery procedures
YELLOW
CAUTION
Hardware detected system in a low
power state or lacking sufficient air
pressure.
One of the following conditions exists:
A. Not Flashing – doors are open.
B. Flashing – Low-pressure sensor
has been activated.
C. Custom-programmed condition
has triggered yellow light.
A. Normal condition – no correction
needed.
B. Reset Interlock System.
1. Close doors or remove
obstruction.
2. Select correct Interlock mode
for your application.
C. Check your facility air supply.
GREEN
OPERATION
The system is fully operational with
the front doors closed. Interlock is at I.
Normal condition – no correction
needed.
BLUE
USER DEFINED
(Examples below)
A. Low fluid in syringe.
B. Custom-programmed condition
has triggered blue light.
USER DEFINED
A. System needs attention. Replace
with new syringe.
B. See custom-programmed
condition recovery procedures,
or see production supervisor.