Special Options 13-15
Fluid Level Sensor Setup
Hardware Setup
The Fluid Level Sensor includes a mounting bracket that can either clip directly onto the fluid cartridge or
to the valve bracket. On the back of the sensor is a screw that can be adjusted so that the sensor rests as
close to the fluid cartridge as necessary. The power cord plugs into the Dispensing Head. Ensure that the
magnet is properly installed on top of the follower, inside of the fluid cartridge.
Software Setup
During a
Prompted Setup in FmNT, you can configure your production run so that when a low fluid
warning is issued, dispensing continues for a pre-set number of boards before stopping. This releases the
operator from having to monitor fluid level and takes the guess work out of deciding when to change the
syringe. It also ensures that no fluid is wasted by allowing you to calculate exactly how many boards/parts
can be processed using a single fluid cartridge.
?
NOTE When you change the fluid cartridge, it is recommended that you also change the needle
to ensure quality dispensing. It is also recommended that you run a Prompted Setup
procedure and reenter the new pot life information.