User guide

13-6 Special Options
Adjusting Valve 2 Toggle Speed
The airflow that controls Valve 2’s toggle speed (up and down movement) is set for your application at
the Asymtek factory. If you need to readjust this toggle speed, follow the steps below.
CAUTION! This procedure should be performed only by an Asymtek-trained service
technician.
A flathead screwdriver is the only tool needed for this operation.
To adjust the toggle speed of Valve 2:
1. Locate the two quick-disconnect airflow controls on the front of the air cylinder (Figure 13-3).
2. Insert a flathead screwdriver inside each brass connector.
3. Turn the screwdriver to adjust airflow to the desired rate.
4. In FmNT, set Toggle Delay (see Dual-Action Dispensing Head setup, above).
Specifications for Dual-Action Dispensing Head
Valve 1 - Valve 2 spacing
X = 95 mm (3.74 in)
Y = ± 0.25 mm (.001 in)
Z = 11.9 mm (0.47 in)
Work Space (depends on dispensing options) 508 x 406 mm (20 x 16 in)
Height of Carrier or Substrate (depends on
dispensing options
25.4 mm (1.0 in)