5-2 Startup/Shutdown
Production Startup
The following procedure describes how an operator runs a dispensing program with a clean
fluid pump and/or a new syringe. The procedure assumes that the pump and syringe have
been installed on the dispensing head, and that a dispensing program has been created (using
either FMW or CADImport) and saved on the computer hard drive. For more information on
creating and running dispensing programs, see the Fluidmove for Windows Installation and
User Guide and the CADImport for Windows Installation and User Guide.
To start up after a production shutdown:
1. Verify power cord is connected to the dispensing system power manager.
2. Verify EMO button is released.
3. Verify doors and access covers are closed.
4. Verify Safety Interlock System key is in the ON (I) position for production.
5. Turn ON (I) the Main Power Circuit Breaker at the rear of the Century Series system.
6. Press the Start (I) Button on the Control Panel.
7. Turn ON (I) the computer and monitor.
" After a few moments, the Windows Desktop should appear.
8. Turn ON (I) the temperature controller (if needed, HT-1000/HT-2000 and HT-1200-
RTD only).
9. If any programs other than FMW are open, close them.
10. Locate the FMW icon on the Windows Desktop.
11. Double-click on the FMW icon to start FMW.
" If you see a message about motor references, click on OK
OKOK
OK.
" Dispenser will find Home in the 1) Z Axis, 2) Y-Axis, and 3) X-Axis.
This takes about 1 minute.
?
NOTE
Steps 12-16 must be performed on the first startup after initial
installation, or after any hardware changes (including changing the
needle/nozzle or removing the fluid pump for cleaning). If you are
sure that no hardware changes have occurred since your last
programming session, skip Steps 12-16 and continue with Step 17.
12. Click on Configuration.
13. Select Needle Setup
Needle SetupNeedle Setup
Needle Setup.
14. Select Valve Offsets
Valve OffsetsValve Offsets
Valve Offsets, or Calculate Master Offsets
Calculate Master OffsetsCalculate Master Offsets
Calculate Master Offsets.
" If the Calculate Master Offsets
Calculate Master OffsetsCalculate Master Offsets
Calculate Master Offsets command is grayed out (not available), go back to Needle
NeedleNeedle
Needle
Setup
SetupSetup
Setup, select Needle Setup Parameters
Needle Setup ParametersNeedle Setup Parameters
Needle Setup Parameters, click on Calculate Master Offsets
Calculate Master OffsetsCalculate Master Offsets
Calculate Master Offsets, click on OK
OKOK
OK, then
repeat this step.
15. Follow the on-screen prompts (see your Fluidmove manual) until the offsets routine is
complete.
" If you have any questions, consult the On-line Help.