Instruction Manual

12-4 Needle Sensor
Calculate Master Offsets
Calculate Master Offsets is a user-prompted routine that records the location of the Purge
Station, the Weigh Station and XYZ location of the needle using the Needle Sensor and
Height Sensor probe. Refer to Fluidmove for Windows User Guide or see Fluidmove’s
Online Help for more guidance.
To perform Calculate Master Offsets:
1. In the Main window, click on Configuration.
2. Select Needle Setup
3. Select Master Offsets.
" If Valve Offsets is not available, select Setup Parameters and activate Offsets in
the Setup Parameters dialog box.
?
NOTE
If you are changing from Calculate Master Offsets to Valve
Offsets, it is recommended that you exit Fluidmove and restart
before performing the Valve Offsets routine.
4. Follow the on-screen prompts.
" Consult the On-Line Help for assistance.
?
NOTE
You should perform a Calculate Master Offsets routine before
beginning a production run. If you change the needle during a
production run, you only need to perform the shorter Find Needle
XYZ procedure to continue dispensing.