Instruction Manual
11-6 Needle Heater
To install the temperature controller (HT-1000, HT-1200-RTD and HT-2000):
?
NOTE
See the specifications at the end of this section for power
requirements.
1. Place the temperature controller in the workstation into the appropriate slot or on top of
the dispensing system so that the rear panel of the temperature controller faces towards
the back of the dispensing system.
2. Route the heating element J-type thermocouple cable and power cable through the cat
track and to the rear of the dispensing system.
3. Plug the J-type thermocouple cable into the thermocouple connector on the back of the
temperature controller.
4. Plug the power cable into the power connector on the back of the temperature
controller.
5. Plug the temperature controller power cable into the system’s power manager.
Figure 11-7 Needle Heater Connections (not to scale)
CAUTION!
Never plug a J-Thermocouple heat sensor into an HT-1200-RTD
Temperature Controller. This would damage the controller
and/or damage the needle heater.
Thumbscrew
Optional Connections
J-Thermocouple or RTD
Needle Heater
Z-Head
Temperature Controller
Power Manager
J-Thermocouple or RTD
External AC Power
120/220VAC
DC Power
Non E-Stop
Power
E-Stop Power