User Manual

System Specifications 8-3
Rear Conveyor Rail (at extreme rear position)
Front Conveyor Rail
*Y Camera Offset=0in.
for Dispense Jet
X Camera Offset = 79 mm (3.1 in ).
Note: Space between rails varies from 51 419 mm (2
_
16.5 in )
_
.
*Y Camera Offset is an example; actual offset depends on specific valve used.
Purge Cup Offset
= 66 mm (2.6 in ).
Vision Area
508 x 386 mm
(20 x 15.4 in ).
Dispensing Area
508 x 386 mm
(20 x 15.4 in ).
Dispensing and
NO Vision
in this area
Vision and
NO Dispensing
in this area
y( p)
Working Envelope:
Dispensing and Vision
429 x 386 mm
(16.9 x 15.4 in.)
Figure 8-1 Dispensing and Vision Areas (Single Pump)
Rear Conveyor Rail (at extreme rear position)
Front Conveyor Rail
*Valve 1 Y Camera
Offset = 50 mm (2.0 in.)
*Valve 2 Y Camera
Offset = 50 mm (2.0 in.)
X Camera Offset
7 mm (2.25 in )Valve1=5 .
X Camera Offset
mm (4.1 in )Valve 2 = 104 .
Note: Space between rails varies from 51 419 mm (2
_
16.5 in )
_
.
Purge Cup Offset
= 66 mm (2.6 in ).
Vision Area
439 x 429 mm
(17.3 x 16.9 in ).
Valve 1
Dispensing Area
mm
(17.3 x 14.3 in )
x 363439
.
Valve 2
Dispensing Area
439 x 363 mm
(17.3 x 14.3 in ).
Dispensing and
NO Vision
in these areas
Vision and
NO Dispensing
in this area
Dual-Action
Working Envelope:
Dispensing and Vision
284 x 363 mm
(11.2 x 14.3 in.)
*Y Camera Offset is an example; actual offset depends on specific valve used.
Figure 8-2 Dispensing and Vision Areas (Dual-Action Pumps)