6-2 Troubleshooting
System Troubleshooting
Table 6-1 System Troubleshooting
Symptom Possible Cause Recovery
A. Main Power Cable
disconnected.
Check that the Main Power Cable is
connected to an AC source.
B. Main Power Circuit
Breaker turned
OFF.
Turn ON the Main Power Circuit Breaker at
the rear of the system.
C. EMO is depressed.
1. Turn EMO clockwise until it releases.
2. Close doors.
3. Press Start button on Control Panel.
4. Press FIND HOME.
D. Interlock activated
(doors opened or
Light Curtain
obstructed during
dispensing, low air
sensor tripped,
etc.).
1. Close the front doors, or remove
obstruction from Light Curtain.
2. Press RESET. Wait 3 seconds.
3. Press FIND HOME.
1. No power to major
system components.
E. Blown fuse in
dispenser.
Contact Technical Support.
A. Nozzle/needle is
damaged.
Replace nozzle/needle and perform Valve
Offsets or Calculate Master Offsets (see B
below).
B. Nozzle/needle has
been changed.
1. From the FmNT Main Window, click on
Configuration.
2. Select Needle Setup
Needle SetupNeedle Setup
Needle Setup.
3. Select Valve Offsets
Valve OffsetsValve Offsets
Valve Offsets (for DJ-2000) or
Calculate Master Offsets
Calculate Master Offsets Calculate Master Offsets
Calculate Master Offsets (for DV-6000).
C. Camera position
has changed.
Perform Valve Offsets or Calculate Master
Offsets (see B above). If problem persists,
contact Technical Support.
2. Dispenses in the
wrong X and Y
location.
D. X-Y location in
FmNT program is
incorrect.
Have supervisor edit program.