5-4 Startup/Shutdown
Shutdown
You can shut down your Century Series system in two ways:
• Emergency Shutdown
• Production Shutdown (End of Shift) / or Service
Emergency Shutdown
WARNING!
Failure to shut down total power to the Century Series system in an
emergency with EMO and the Main Power Circuit Breaker could
cause serious bodily harm to the user and/or serious damage
to the dispensing system.
During an emergency or malfunction, press EMO--the large red button on the Control Panel
(Figure 4-3 and Table 4-1). Pressing
EMO cuts the power to all major system components
except the computer and monitor.
For more information on emergency shutdown situations and instructions on restoring
system power after an emergency shutdown, see Emergency Shutdown in Section 3 – Safety.