User Manual
4-14 Operation
Table 4-5 Dispensing Status Control Functions (Continued)
Button/Indicator Function
V1V1
VALVE
STATUS
V2
VALVE STATUS LED turns ON if there is a problem
with the fluid pump motor. It usually indicates that the
pump electronics (overcurrent protection circuitry) has
detected a surge of power. When the LED is ON, the
valve is disabled. V1 is Valve 1. V2 is Valve 2.
To recover, press VALVE RESET. If the problem
persists, the pump may need to be cleaned.
Each DV-6000, DV-7000, and DP Series dispensing
valve has a Valve Speed Pot located on the Control
Panel, just to the right of the Dispensing Status
Controls. The Valve Speed Pot sets the valve motor
speed, which affects the amount of fluid dispensed.
Each DP Series valve has an additional Valve Reverse
Speed Pot to adjust the valve motor reverse speed,
determining the valveās refill rate. These control pots
are located at the rear of the machine, on Electrical
Interconnect Panel. The pot labeled Elec. 7 controls
Valve 1 reverse speed; Elec. 8 controls Valve 2
reverse speed.
Note: Speed Controls are not used with the DJ-2000.
VALVE
RESET
Press VALVE RESET after you have corrected any
problem indicated by the Valve Status indicators.