User Manual
Operation 4-13
Table 4-5 Dispensing Status Control Functions
Button/Indicator Function
RESET
CONVEYOR
STATUS
PAUSE
CONVEYOR STATUS has two buttons. PAUSE halts
the conveyor, and its LED indicates that the Conveyor
has been paused. Press PAUSE to resume conveyor
movement.
Press RESET to clear the controller after a fault
condition has occurred.
INTERLOCK
INTERLOCK
RECOVERY
INTERLOCK is a key-activated safety feature that
prevents the conveyor and the dispensing head from
moving while the access doors are open. During
dispensing operations, this helps prevent personal
injury or damage to the dispensing system. For more
information on INTERLOCK, see Section 3 – Safety.
RESET
DISPENSER
STATUS
DISPENSER STATUS LEDs are color coded for each
dispensing status condition. For an explanation of the
different status conditions, see Table 4-6.
Press DISPENSER STATUS RESET after the
condition that triggered the red “abort” LED has been
corrected. This will reset the dispenser electronics.
NOTE: After you press the DISPENSER STATUS
RESET button, you must press the FIND HOME
button to re-establish motor references.
(Continued next page)
Program
Paused
Fault
Condition