Rear View Features
Following are short descriptions of the various features of the dispensing system (shown in
Figure 2-4 and Figure 2-5) and their functions. Detailed operation instructions for some
features are covered in other sections.
Air Filter and Water Trap
The Air Filter and water trap removes particles and impurities in the facility air supply.
Conveyor Air Gauge and Regulator
The Conveyor Air Gauge indicates the air pressure supplied to the bar clamps and stop pins
on the conveyor. The Conveyor Air Regulator is located under the gauge. The recommended
setting is 3.9 kg/cm
2
(55 psi).
Fan
The Fan removes the hot air from the dispensing area.
High Air Pressure Relief Valve
The High Air Pressure Relief Valve is a safety valve that opens when the incoming air
pressure exceeds 690kPa (100 psi).
Hour Meter (option)
The Hour Meter monitors the dispensing system operation hours for maintenance logging.
Low Air Pressure Sensor (option)
The Low Air Pressure Sensor automatically detects low air pressure to the dispensing
system. During dispensing, when the air pressure goes below a factory preset level, the
sensor activates the interlock safety system, which stops all motion and aborts the
dispensing program. The Light Beacon and the dispenser status LED’s on the control panel
light up. To recover, see Table 6-1.