User Manual

13-8 Dual-Action Dispensing Head
Changing Fluid Valve Spacing
To maximize your dispensing area, the space between Valve 1 and Valve 2 is set up for your
application at the Asymtek factory. Depending on your fluid valves and accessories, you can
separate the valves 100 mm (3.72 in) or 87 mm (3.42 in) (See Figure 13-3).
For details on this procedure, contact Asymtek Technical Support.
Adjusting Valve 2 Toggle Speed
The airflow that controls Valve 2’s toggle speed (up and down movement) is set for your
application at the Asymtek factory. If you need to re-adjust this toggle speed, follow the
steps below.
WARNING!
This procedure should be performed only by an Asymtek-trained service
technician.
The only tool needed for this operation is a flathead screwdriver.
To adjust the toggle speed of Valve 2:
1. Locate the two quick disconnect airflow controls on the front of the air cylinder. (See
Figure 13-3).
2. Insert a flathead screwdriver inside each brass connector.
3. Turn the screwdriver to adjust airflow to the desired rate.