User Manual

Dual-Action Dispensing Head 13-5
Setup
The Dual-Action Dispensing Head is installed at the Asymtek factory or at your facility by
an Asymtek Field Service Engineer. Fluidmove software guides you through a one-time set
up, which establishes the offsets between the fluid pumps and Z-axis heights for the Height
Sensor probe, if equipped.
The Fluidmove for Windows NT (FmNT) application has a specific procedure for setting up
the Dual-Action Dispensing Head.
The setup process is essential ONLY under the following circumstances:
First-time system installation
Fluid pump replaced
Height Sensor installed and probe moved in Z-direction
Download Program memory erased or corrupted
Needle Sensor removed
Needle type changed
System configuration changes (i.e. Z-Head adjustments)
CAUTION!
The needle will hit the substrate, workpiece or component if the
dispense gap parameter for dots and lines is not greater than 0.0.
See Fluidmove User Guide for line / dot parameter adjustment
procedures.