12-6 Needle Heater
Installation
On dispensing systems equipped with needle heaters, the needle-heating element plugs into
outlets on the dispensing head. If your dispensing system is not equipped with needle
heaters, a separate temperature controller is used and will need to be installed, along with a
matching needle heater. Follow the procedure below. For most Century Series dispensing
systems,
see Section 3 – Accessories Installation in the Century Series Installation Manual
for instructions on installing the temperature controller.
WARNING!
Only a trained service technician should perform these installation
procedures.
To install the temperature controller (HT-1000, HT-1200-RTD and HT-2000):
?
NOTE
See the specifications at the end of this section for power
requirements.
1. Place the temperature controller in the workstation into the appropriate slot or on top of
the dispensing system so that the rear panel of the temperature controller faces towards
the back of the dispensing system.
2. Route the heating element J-type thermocouple cable and power cable through the cat
track and to the rear of the dispensing system.
3. Plug the J-type thermocouple cable into the thermocouple connector on the back of the
temperature controller.
4. Plug the power cable into the power connector on the back of the temperature
controller.
5. Plug the temperature controller power cable into the system’s power manager.