User Manual

10-14 Height Sensor
Specifications
Height Compensation Accuracy
Z-Axis Velocity Z-Axis Acceleration Repeatability
100 mm/sec
(4 in/sec)*
7.5 m/sec
2
(300 in/sec
2
)*
± 0.051 mm 3 sigma
(± 0.0020 in)
50 mm/sec
(2 in/sec)*
7.5 m/sec
2
(300 in/sec
2
)*
± 0.038 mm 3 sigma
(± 0.0015 in)
25 mm/sec
(1 in/sec)*
2.5 m/sec
2
(100 in/sec
2
)*
± 0.026 mm 3 sigma
(± 0.0010 in)
Force 5 grams (0.18 oz)
Probe Diameters 1.59 mm (0.0625 in)
1.91 mm (0.0750 in)
Probe Retract Adjustable 5-10 mm (0.2-0.4 in)
Environmental Range
5-50°C 95% RH (below 40°C)
Compatibility with Asymtek
Products
A-400 and A-600 Automoves, all dispensing valves,
Needle Heater, Needle Sensor and AV-700 or AV-
2550 Vision Systems
*Velocities above 50 mm/sec (2 in/sec) and accelerations above 7.5 m/sec
2
(300 in/sec
2
) can
result in large repeatability errors.