9-14 Vision System
Environment
10–55°C (50–131°F)
10–85% RH (below 40°C (104°F))
Light Sources
Light Ring, red LED visible light
Dual Light (option)
NER Diffused On Axis Light (option)
Camera
All systems 25-mm lens, adjustable f-stop
Focal length 43 mm (1.7 in)
Focus Height Range See Figure 9-3
Fiducials Location
Fiducial Form Standard or complex (edge or model)
Fiducial Define Teach Mode
Fiducial Search Based on results, programmable to accept or skip workpiece
Fiducial Find <500 msec maximum per site
(150 msec typical)
Search Range 14.7 x 12.2 mm (0.58 x 0.48 in)
Accuracy
±0.025 mm (0.001 in)
Angular Correction
± 7 degrees