User Manual

9-6 Vision System
Minor Troubleshooting
There are some troubleshooting procedures that an operator may perform. These are listed in
Table 9-2. Some symptoms that appear to be problems with the vision system may actually
have other causes. Refer unsolved problems to a service technician.
Table 9-2 AV-700 Troubleshooting
Symptom Check/Correction
No image
Make sure that the lens cap has been removed from the camera.
Check the camera cable harness connection at the back of the
dispensing head.
Check the two cable connections (part of the tie-wrapped harness
connecting the computer to the camera and light ring). The 12-pin
cable connects the computer to the camera, providing power and
video feed. The 15-pin D-sub cable connects the computer to the
light ring.
Unfocused image
Adjust the focus.
Check to make certain that the substrate is within the height focus
limits of the system (see AV-700 specifications).
The camera lens may have been dropped, damaged from harsh
chemicals or the environment, or has hit objects during operation.
Call a service technician.