Quick Operations Owner manual
16 Component Description
Table 3-4 Rear View Features
Item Name Description
1
Main Air
Regulator and
Gauge
The Main Air Regulator (T-bar) controls, and the gauge indicates, the
amount of air pressure supplied to the dispensing system.
Recommended Setting: 551-620 kPa (80-90 psi)
2
Conveyor Air
Gauge and
Regulator
The Conveyor Air Regulator controls, and the gauge indicates, the air
pressure supplied to the bar clamps and stop pins on the Conveyor.
Recommended Setting: 3.9 kg/cm2 (55 psi)
3
Main Power
Circuit Breaker
Controls all electrical power to the dispensing system.
I = ON
0 = OFF
4
Main Power
Inlet/Cable
Connects the dispensing system to the facility power supply.
5
Pressure Relief
Valve
A safety valve that opens when the incoming air pressure exceeds 690kPa
(100 psi).
6
Air Filter &
Water Trap
Removes particles and impurities in the facility air supply.
7 Main Air Inlet Connects the dispensing system to the facility air supply.