Manual
Height Sensor 10-1
10
Height Sensor
The Retractable Adjustable Height Sensor (HS-Series RTA) is located on the dispensing
head next to the needle. It checks and records substrate height to help maintain consistent
dispensing height on a non-level or warped substrate. Consistent dispensing height is
essential to ensure consistent dispensing quality.
If your system includes this option, it should have been installed at the Asymtek factory
prior to shipping. However, if you have upgraded to include a Height Sensor, or need to
reinstall it, refer to the installation section below.
Figure 10-1 Height Sensor
Probe
S
olenoid
Micrometer
Locking Screw
Micrometer
Adjustment
Mounting Bracket
Probe Set Screw
LED Indicator