Manual

Safety 4-7
Electrical Power
Electrical power is supplied to the system through the Main Power Cord. The Main Power
Cord connects the facility AC power source to the Main Power Inlet located on the back of
the Century Series system (see Figure 2-5).
All personnel working on or around the Century Series system should be
aware of all electrical power supply sources
.
To turn the Main Power
ON
or
OFF
, use the Main Power Switch located on the back of the
Century Series system (see Figure 2-5). Turning the Main Power
OFF
cuts power to all
components connected to the Power Manager. (The Vision System, heater controllers and
computer system are not usually connected to the Power Manager.) The position indicates
ON
. The position indicates
OFF
.
When performing service or maintenance work on the machine in areas
marked with the Electrical Warning Label, it is strongly recommended that
the Main Power Switch be turned OFF.
Air Pressure Relief Valve
In some circumstances, factory air supplied to the dispensing system may fluctuate. The Air
Pressure Relief Valve opens to relieve system air pressure if it exceeds 690 kPa (100 psi). At
828 kPa (120 psi), this valve is completely open to relieve excess air pressure.
Never exceed the Century Series system maximum pressure of
621 kPa (90 psi). Failure to observe the maximum pressure limit
could cause serious bodily harm to the Operator.
.
Other Safety Options
Refer to Section 13 - Special Options, for detailed operation information about other
available Asymtek safety options.