Special Options 13-17
Operation Controls
If you need to change the Main Air pressure, refer to “Adjusting Air Pressures” in
Section 3 – Operation.
To set the low pressure valve to trigger the sensor, follow the instructions below. You need a
flathead screwdriver to complete this adjustment.
To set the low pressure set point:
1.
Set the system pressure with the Valve Pressure or Fluid Pressure regulators to the
low kPa (psi) at which you want to trigger the alarm.
Refer to “Gauges and Regulators” in Section 3 – Operation for instructions on
how to properly set pressure.
2.
Slide the collar down on the Low Air Pressure Alarm sensor.
3.
Turn
Safety Interlock
ON
( ).
The System Status green LED indicator on the Control Panel and on the Light
Beacon will turn ON.
4.
Using a flathead screwdriver, turn the brass sensor adjuster counter-clockwise until
the sensor is triggered and the System Status yellow LED indicator and light beacon
Turn ON.
5.
Adjust the Main Air to the desired pressure.
The System Status yellow LED indicators and the Light Beacon will turn OFF
and the green LED will turn ON.