Manual

Special Options 13-11
O
O
O
O
O
O
Figure 13-4 HT-2000 Temperature Controller
Theory of Operation
The Vacuum Switch activates a Venturi-type generator that provides a vacuum to the
part through the holes on the tooling plate. The Temperature Controller brings the
temperature of the tooling plate to a preset temperature which then remains constant.
Heat is applied by contact of the tooling plate to the part. The Vacuum Switch
deactivates the vacuum and the part is removed from the dispensing area.
Operation Controls and Adjustments
The vacuum air is adjustable by closing or opening the air holes in the tooling plate. The
temperature can be adjusted by the Heat Controller at any time.
The Vacuum Heated Tooling Plate can get very hot and remain hot for
some time after being turned OFF. Never touch it while the Century
Series system is ON or for one hour after the system has been turned
OFF.