Owner manual

Introduction 1-5
Table 1-2 Control Panel Functions
Button/Switch Function
I
The Start and Stop buttons are located on the Control Panel and control
power to major system components.
" NOTE During power-up, there is a 60 second delay to allow the
dispensing system to vent properly
.
ABORT
ABORT halts a production run. After you press the ABORT button, its red LED
lights to indicate that the currently loaded program has been discontinued.
RESET
After a program is aborted you must press RESET before you can restart the
program.
" NOTE After you press the RESET button, you must press the FIND
HOME button to reestablish motor references.
PAUSE
PAUSE temporarily stops a production run. When its yellow LED indicator is
ON, the system is paused. You can pause a production run at any time. To
resume dispensing, press PAUSE again. When the LED indicator turns OFF,
the system resumes dispensing.
INTERLOCK
The Interlock is a key-activated safety feature that prevents the Dispensing
Head from moving while the dispensing system front doors are open.
The Interlock should always be ON during normal operation. This helps
prevent personal injury or damage to the dispensing system.
FIND
HOME
FIND HOME sends the Dispensing Head to either its XYZ or its Z machine
origin.
When you press one of the motion control buttons, the Dispensing Head
moves as follows:
Moves the Dispensing Head to the back in small increments.
Moves the Dispensing Head to the front in small increments.
Moves the Dispensing Head to the right in small increments.
Moves the Dispensing Head to the left in small increments.
Z-AXIS
Fast Mode
Button
Z-AXISZ-AXIS
Fast Mode
Button
" NOTE Pressing the Fast Mode Button and one of the arrow keys
simultaneously moves the Dispensing Head in large
increments.