Owner manual

Specifications 7-1
7 Specifications
Overview
Century C-341 Dispensing System specifications are presented in Table 7-1 and Table 7-2. These
specifications are intended as a convenient reference for personnel planning system relocation,
installation, or operation, and others that may have an interest in system performance characteristics. This
section provides specifications for the following:
Facility Requirements
System Specifications
Safety First
Familiarity with the performance specifications and facility requirements in this section can provide
information leading to safe operation of the dispensing system. For additional safety information, refer to
the Safety section.
Facility Requirements
Table 7-1 Facility Requirements
Facility Requirements
System Footprint 917 x 1041 mm (36 x 41 in.)
Compressed Air Dry;
40° F Dew Point
620 kPa (90 psi, 6.2 Bar), up to 85 l/min (3 SCFM) maximum,
depending on configuration
Ventilation Air Exhaust 0.28 m
3
/s @ 25 mm water column (600 SCFM @ 1.0 in. water column)
Nitrogen Source
Required for moisture-sensitive materials–620 kPa (90 psi, 6.2 Bar),
up to 340 l/min (12 SCFM)
Main Power Supply 100/120/230/240 VAC, 50/60 Hz, 10 A
Noise <70 dBA
System Weight 204 kg (450 lbs.)
Standards Compliance CE