6-2 Troubleshooting
Table 6-1 Basic System Troubleshooting (continued)
Symptom Possible Cause Recovery
A. System is in abort mode.
1. Press
RESET. Wait three seconds.
2. Press
FIND HOME.
- If motion occurs, restart the
dispensing program.
- If no motion occurs, call a service
technician.
No response from
Control Panel
buttons
B. Interlock activated (doors
opened during dispensing).
1. Close both doors.
2. Press
RESET. Wait three seconds.
3. Press
FIND HOME.
- If motion occurs, restart the
dispensing program.
- If no motion occurs, call a service
technician.
A. Product program still running
when doors are opened.
System aborts
when loading or
unloading boards
B. Robot not parked over Robot
safe sensor when doors are
opened.
1. Close both doors.
2. Press
RESET. Wait three seconds.
3. Press
FIND HOME.
- If motion occurs, restart the
dispensing program.
If no motion occurs, call a service
technician.
Safety Interlock
fails to reset
Interlock activated.
1. Close both doors.
2. Press
RESET. Wait three seconds.
3. Press
FIND HOME.
- If motion occurs, restart the
dispensing program.
- If no motion occurs, call a service
technician.
A. Micro-adjust knob is fully
closed.
Open micro-adjustment to characterized
setup value (value between 1 and 12
marks of turn).
B. Applicator ON/OFF button is
OFF.
Press
Applicator ON/OFF button.
C. Out of fluid. Add fluid to reservoir.
D. Nozzle is clogged.
Remove nozzle, visually verify that it is
clogged. See Fluid Dispensing Applicator
manual for cleaning instructions.
E. Not enough fluid pressure or no
fluid pressure.
Increase fluid pressure. If equipped with
Material Change Over option, verify valves
are set to correct reservoir.
F. Pump not running. Verify pump air pressure is sufficient.
Applicator does
not operate or no
fluid dispensed
G. Pressure to Fluid Reservoir is
turned OFF.
Turn the Reservoir Air Pressure Switch to
the ON position.
No air pressure
System not connected to facility air
supply.
Connect the Main Air Inlet to a facility air
supply.