Owner manual

Maintenance 5-3
Changing Material /Flushing Fluid System
To change material and flush the Fluid System:
1. If applicable, turn OFF the heater and allow the fluid to cool for at least fifteen minutes.
2. Turn OFF air pressure to the Fluid Reservoir by turning the Reservoir Air Pressure Pneumatic
Switch to the OFF position or by reducing pump fluid pressure to 0 psi.
3. Empty the remaining material from the reservoir.
4. Fill the reservoir with appropriate solvent.
5. Turn ON air pressure to the Fluid Reservoir by turning the Reservoir Air Pressure Pneumatic
Switch to the ON position or by increasing pump fluid pressure.
6. Purge solvent through the fluid system until the Fluid Reservoir is empty.
7. Turn OFF air pressure to the Fluid Reservoir as described in Step 2 above.
8. Inspect the fluid filter. Clean and replace as needed.
9. Repeats Steps 3 through 7 as necessary.
10. Fill the Fluid Reservoir with new material.
11. Turn ON the Fluid Applicator until all air is purged from the system.