Owner manual
5-2 Maintenance
Filling the Fluid Reservoir
To fill the Fluid Reservoir:
1. Turn the Reservoir Air Pressure Pneumatic Switch to the
OFF (0) position.
2. Relieve residual pressure in the Fluid System by opening the Fluid Pressure Relief Valve on
the Fluid Reservoir.
3. Open the lid and check that the reservoir is clean and free from foreign materials.
WARNING! Solvent vapors may be released when the lid is open.
4. Add fluid up to a maximum of 25 mm (1 in.) below the rim of the opening.
5. Close the lid immediately after filling.
Item Description
1 Pressure Relief Valve
2 Fluid Reservoir
3 Cartridge (inside)
Figure 5-1 Fluid System
2
3
1