Owner manual
4-2 Operation
System Startup/Shutdown
This subsection details basic start-up and shutdown procedures based on different levels of operation.
Your actual start-up and shutdown procedures may vary.
WARNING! Only authorized service technicians or process engineers should connect power
cables to the power source. Operators should not attempt to make electrical
connections.
System Startup
If necessary, refer to the figures in the Introduction section to identify system components.
To power on the dispensing system:
1. Verify that the main power cord is connected to the Main Power Inlet and the facility
power source.
2. Verify that the facility air hose is connected to the Main Air Inlet.
3. Verify that the Facility Exhaust Ventilation ductwork is connected to the Exhaust Vent Duct.
4. Turn the Main Power Switch on the back of the system to the
ON (I) position.
5. Turn the Computer power switch to the
ON (I) position.
6. Verify that the Safety Interlock System key is in the
ON (I) position for production.
7. Check the EMO button to see if it has been activated. If it has been activated, deactivate it by
turning the red knob counterclockwise until the knob pops out.
8. Close the dispensing system front doors and access covers.
9. Press
Start on the Control Panel.
" NOTE The dispensing system turns on after an approximate 60-second vent air time
delay.
! The dispensing system should be in a powered-up state. If not, make sure the power cord
is properly connected to the dispensing system and to an active facility power source.
! The system computer should begin the boot up sequence.
10. Press
Find Home on the Control Panel.
! The Robot should move to the extreme front left corner of the dispensing area.