Installation Manual
5-32 Power-up and Testing
To check vacuum for Contact Heaters (X-1020 only):
WARNING! The Heaters may be hot. Use caution when working in the area of the Heaters or
serious burns may result.
? NOTES This procedure assumes the following:
• Sample workpieces are on the Conveyor in the pre-dispense, dispense, and
post-dispense stations as applicable to your system configuration
• The dispensing system Hatch is open
• Monitor displays Station I/O Diagnostic tab of MPC555 I/O Diagnostic dialog box
1. Raise all Lift Tables as described in the previous procedure.
2. In the Station I/O Diagnostic dialog box, locate the
Vacuum output buttons. See Figure 5-9.
3. Activate the vacuum in each Conveyor station by clicking on the
Vacuum buttons.
4. Test the vacuum for each Heater by clicking on the
Vacuum button in each Conveyor station
and trying to move the sample workpiece.
> The workpieces should not be easily moved off of the Contact Heaters.
5. Click on OK in the Station I/O Diagnostic dialog box and then click on OK to return to the
Main Window.
6. Manually unload all of the sample workpieces.
To check overall Conveyor component operation:
1. Place a sample workpiece in the pre-dispense station without activating the Board Sensor.
2. Close the dispensing system Hatch.
3. In the FmNT Main Window, click on
Teach a Program.
4. In the Programming Window, click on the
Load a Board icon .
5. Make sure that the Stop Pins, Lift Tables or Clamp Bars, and Heater Tooling function
correctly during the loading process as follows:
> The Stop Pins, Clamp Bars, and Lift Tables should all raise and lower smoothly. The
front and rear Clamp Bars in each Conveyor station should be synchronized to raise and
lower the workpiece in unison.
> The workpiece should contact the Stop Pins gently without bouncing off.
> The Heater Tooling should come on and go off at the proper times.
> If applicable, the Contact Heater vacuums should come on and go off at the proper times.