Installation Manual
Power-up and Testing 5-29
10. In the SMEMA Diagnostic dialog box, locate the upstream and downstream bits. Perform
the actions specified in Table 5-2 and verify the results. If the results were not as specified,
check all TS-01 connections and retest.
Table 5-2 SMEMA Communication Test Matrix
Action Result
In dialog box, press Request Board
from Upstream Tool output button.
No. 2 LED on TS-01 comes ON.
Press TS-01 button No. 3.
Dialog box “Board Available from
Upstream Tool” input changes to ON.
In dialog box, press Board Available to
Downstream output button.
No. 4 LED on TS-01 comes ON.
Press TS-01 button No. 5.
Dialog box “Downstream Tool Requests
Board” input changes to ON.
11. If results are not as specified, check all TS-01 connections and retest. If results are still
negative, refer to “Troubleshooting Conveyor” in the Troubleshooting section of this manual.
Item Description
1 Computer Network Cable
2 Upstream SMEMA Port
3 Downstream SMEMA Port
4 TS-01 Cables
5 TS-01 I/O Test Box
Figure 5-16 TS-01 I/O Test Box Connections
3
4
5
1
2