Installation Manual
5-28 Power-up and Testing
To rough-adjust Conveyor Rail width:
1. When the rails are determined to be level with dispensing system mechanics, obtain a sample
workpiece identical to the one that will be used during production.
2. Narrow or widen the spacing between the Conveyor Rails to fit the sample workpiece
as follows:
a. In the Jog Commands dialog box, click on
Conveyor.
b. Use the Y-axis fast jog buttons
to adjust the rail width to the approximate width of
the sample workpiece.
c. When the rails are at the approximate distance apart, open the Hatch and place the
workpiece on the Conveyor Belts.
d. Close the Hatch and use the Y-axis slow jog button
to finish adjusting the rail width.
> Rail width should allow the workpiece to rest on the belts as close to the rails as
possible, allowing space for smooth, non-binding movement along the Conveyor and
for heat expansion of the workpiece.
3. Close the Jog Commands dialog box to return to the Tools Window.
4. In the Tools Window, click on the
Return to Main Window icon .
5. Remove the workpiece from the Conveyor.
To check Conveyor upstream and downstream SMEMA communication:
1. Perform a Service Shutdown as specified in the Safety section of this manual.
2. Attach the TS-01 upstream and downstream cable adapters to the TS-01 I/O Test Box.
3. Attach the TS-01 upstream and downstream cables to the appropriate SMEMA connectors at
the rear of the dispensing system. See Figure 5-16.
4. Make sure that all of the
I↔
↔↔
↔O/INDEP switches along the edge of the TS-01 I/O Test Box are
all set to
INDEP. See Figure 5-16.
5. Perform a Post-Service Start-up as specified in the Safety section of this manual.
6. Make sure that the
DRIVERS/OPTO I/O switch in the corner of the TS-01 I/O Test Box is set
to
OPTO I/O.
7. In the FmNT Main Window, click on
Configuration and then select Setup Conveyors.
8. In the Setup Conveyors dialog box, verify the Conveyor type is set at
MPC555, and then click
on the
Test I/O button. See Figure 5-9.
9. When the MPC555 I/O Diagnostic dialog box opens, select the
SMEMA Diagnostic tab.