Installation Manual
Power-up and Testing 5-25
To check fixed-width Conveyor clearance, Safety Interlock, and X-axis movement:
CAUTION! Perform the following procedure only if your dispensing system has been
configured for an application that requires a fixed Conveyor width. DO NOT
perform the procedure for adjustable-width Conveyor configurations.
? NOTE This procedure assumes that you are already in the FmNT Tools Window. If not, refer to
the first two steps in the Needle Sensor test procedure.
1. Verify electrical cables and pneumatic lines near the Conveyor are not in danger of being
pinched or snagged during Conveyor operation.
2. In the FmNT Tools Window, click on the
Jog icon .
3. In the Jog Commands dialog box, click on
Conveyor. See Figure 5-14.
4. Open the dispensing system Hatch.
> The green Beacon light should go OFF and the yellow Beacon light should come ON.
5. In the Jog Commands dialog box, click on both the slow
and the fast X-axis jog
buttons to try to move the Conveyor Belt in both directions. See Figure 5-14.
> There should be no movement of the Conveyor Belt.
6. Close the dispensing system Hatch.
7. In the Jog Commands dialog box, click on both the slow
and the fast X-axis jog
buttons to move the Conveyor Belt in both directions. See Figure 5-14.
> The Conveyor Belt should move smoothly in both directions with no slipping on
its pulleys.
8. Close the Jog Commands dialog box to return to the Tools Window.
9. In the Tools Window, click on the
Return to Main Window icon .
To verify Conveyor Rails are level with dispensing system mechanics:
? NOTE This procedure assumes that the Conveyor Rail is in the Home position and that the
Height Sensor has been functionally tested.
1. In the FmNT Main Window, click on the
Configuration button and select Setup
Height Sensor
.
2. In the Height Sensor Configuration dialog box, click on
CAN-HS. See Figure 5-10.
3. In the second Height Sensor Configuration dialog box, click on the
ARM/DISARM button.