Installation Manual

5-18 Power-up and Testing
10. Using the X- and Y-axis position controls only, move the Dispensing Head around the
dispensing chamber.
> The Dispensing Valve needle tip and Height Sensor Probe should not contact any Board
Sensor, Stop Pin, electrical line, or pneumatic line in the dispensing chamber.
11. Close the Jog Commands dialog box and then raise the Height Sensor Probe as follows:
a. In the FmNT Main Window, click on the
Configuration button and select Setup
Height Sensor
.
b. In the Height Sensor Configuration dialog box, click on
CAN-HS.
c. Click on
Arm/Disarm until the “Current Arm State” reads DISARMED. Then click on OK
twice to return to the Main Window.
> The Height sensor probe should be in the retracted position.
To test the Safety Interlock effect on the Dispensing Head:
1. In the Main Window, click on the
Jog icon .
2. In the Jog Commands dialog box, verify the
Dispenser radio button is selected and then click
on the
Home button. While the Dispensing Head is moving toward its home position, open
the Hatch. See Figure 5-11.
> The green Beacon light should go OFF, the yellow Beacon light should come ON, and
the Dispensing Head should stop moving.
3. Close the dispensing system Hatch.
> The yellow Beacon light should go OFF, the green Beacon light should come ON, and
the Dispensing Head should continue moving toward its home position.
To test Dispensing Head movement:
1. In the Jog Commands dialog box, click inside of the Target Box in three or more locations.
> The Dispensing Head should smoothly move to the chosen locations.
2. Click on both the slow
and the fast X-and Y-axis jog buttons to move the
Dispensing Head to the extreme X and Y limits of travel.
> No unusual vibrations should occur during Dispensing Head motion.
> The Dispensing Head should move freely about the dispensing chamber.
> The cable cat track should not impede Dispensing Head motion.
3. Use both the slow
and the fast Z-axis jog buttons to move the Dispensing Head up
and down.
CAUTION! The downward travel of the Dispensing Head must not exceed 3.5 inches
(88 mm) or damage to components will occur.