Installation Manual

5-16 Power-up and Testing
Dispensing Head and Accessories
Perform the following procedures check function of the Dispensing Head, its accessories, and the
Safety Interlock.
To check Dispensing Head clearance:
1. Open the Hatch, place a production sample workpiece in the dispense station of the
Conveyor, and then close the Hatch.
2. In the FmNT Main Window, click on
Configuration and then select Setup Conveyors.
3. In the Setup Conveyors dialog box, click on the
Test I/O button. See Figure 5-9.
4. In the MPC555 I/O Diagnostic dialog box, select the
Station I/O Diagnostic tab.
5. In the Station I/O Diagnostic dialog box, click on the dispense station
Clamp/Lifter button to
raise the Lift Table or Clamp Bar. See Figure 5-9.
> This action clamps the workpiece in place at its actual dispense height.
6. Click on
OK twice to return to the Main Window.
Figure 5-9 Conveyor Setup Dialog Boxes