Installation Manual

Power-up and Testing 5-13
5. Verify all green power LEDs on the XY Servo Interface Board are illuminated.
See Figure 5-7.
6. Press the EMO button on the front of the dispensing system.
7. On the Main Interface Board, verify the +24V green power LED goes OFF and all other
power LEDs stay ON.
> Some of the power LEDs may take longer to deactivate than others. Give them a few
seconds to completely go OFF.
8. On the XY Servo Interface Board, verify the +24V, +24V_A&B_ISO, and +SERVO power
LEDs go OFF and all other LEDs stay ON.
9. Restore power to the dispensing system by turning the red EMO knob counterclockwise until
it pops out and then pressing the green
ON (l) button on the Operator’s Console.
10. Repeat Steps 7 through 9 using the rear EMO Switch.
11. Close the side door of the Computer and then close the Front Cabinet Door.
12. Replace the Servo Shelf Cover.
Item Description
1 Power LEDs
2 XY Servo Interface Board
3 Servo-shelf
Figure 5-7 Power LED Location on the XY Servo Interface Board
3
1
2