Installation Manual
Table 2-4 Beacon Color Indications
Beacon Color System Status Recovery Procedure
ALERT
All motion, outputs, Dispensing Valve,
and motion controls are disabled.
One of the following conditions exist:
A. Solid – System in an Emergency
Stop condition.
A. 1. Remedy problem causing the
Emergency Stop.
2. Reset EMO button(s).
3. Restart the dispensing system.
B. Flashing – Software driven error
message is displayed on the
Computer Monitor.
B. Respond to error message. Refer to
FmNT User Guide or Online Help.
RED
(Audible Alarm)
C. C. Custom-programmed condition
has triggered the red light.
Refer to programmer’s recovery
procedures.
CAUTION
System in a low power state or lacks
sufficient air pressure.
One of the following conditions exist:
A. Solid – Hatch is open. A. Close Hatch. Production run will start
where it left off.
B. Flashing – Low-pressure Sensor
has been activated.
B. Check facility air supply.
YELLOW
C. Custom-programmed condition
has triggered yellow light.
C. Refer to programmer’s recovery
procedures.
GREEN
OPERATION
The system is fully operational with
the Hatch closed.
Normal condition – no correction
necessary.
USER DEFINED
(Examples Below)
(Flashing Light is the Default)
A. Low fluid level in syringe. A. Replace syringe.
BLUE
B. Custom-programmed condition
has triggered blue light.
B. Refer to programmer’s recovery
procedures.
2-22 Safety