Installation Manual
10-34 Parts Replacement
15. Perform component functional tests as specified in Table 10-3.
> If any component fails the functional test, check all connections and retest. If the
component still fails, perform fault isolation in accordance with the Troubleshooting
section of this manual.
Table 10-3 Dispensing Head Functional Test Procedures
Component Test Procedure
Height Sensor
Refer to Power-up and Testing section of this manual.
Vision System
Refer to Power-up and Testing section of this manual.
Dispensing Valves As specified in the applicable Dispensing Valve
Installation and Operations Manual.
Dispensing Head The following Dispensing Head test procedures in the
Power-up and Testing section of this manual:
• Final Clearance Check
• Interlock Effect Test
• Movement Test
• Dispensing Valve Pneumatics
16. Perform Camera focus adjustment, leveling, and calibration in accordance with the
Calibration and Adjustment section of this manual.
17. Perform a Valve Offsets routine in accordance with the FmNT User Guide.