Installation Manual

10-34 Parts Replacement
15. Perform component functional tests as specified in Table 10-3.
> If any component fails the functional test, check all connections and retest. If the
component still fails, perform fault isolation in accordance with the Troubleshooting
section of this manual.
Table 10-3 Dispensing Head Functional Test Procedures
Component Test Procedure
Height Sensor
Refer to Power-up and Testing section of this manual.
Vision System
Refer to Power-up and Testing section of this manual.
Dispensing Valves As specified in the applicable Dispensing Valve
Installation and Operations Manual.
Dispensing Head The following Dispensing Head test procedures in the
Power-up and Testing section of this manual:
Final Clearance Check
Interlock Effect Test
Movement Test
Dispensing Valve Pneumatics
16. Perform Camera focus adjustment, leveling, and calibration in accordance with the
Calibration and Adjustment section of this manual.
17. Perform a Valve Offsets routine in accordance with the FmNT User Guide.