Installation Manual

Parts Replacement 10-23
10. Remove the Balance Module from the dispensing chamber as follows (see Figure 10-12):
a. Remove four 4-mm socket head cap screws attaching the Balance Module to the
Conveyor Base Plate.
b. Disconnect the Balance Module Cable from the Scale Interconnect Cable.
c. Carefully slide the Balance Module towards the back of the dispensing chamber, lift it
around the front Conveyor Rail, and remove it from the dispensing chamber.
? NOTE The faulty Balance Module should be returned to Asymtek. Refer to “Return
Material Authorization in this section for merchandise return instructions.
Item Description
1 Mounting Screw (4 total)
2 Balance Module
3Conveyor Base Plate
4 Front Conveyor Rail
5 Balance Module Cable
Figure 10-12 Removing/Installing the Balance Module
1
3
2
5
4