Installation Manual

Parts Replacement 10-19
Item Description
1 Dispensing Area Front Cover
2 Quick-release Fastener (1 of 6)
3 Mounting Brackets
Figure 10-8 Removing/Installing the Dispensing Area Front Cover
6. Turn each of the six Phillips head fasteners on the Dispensing Area Front Cover 1/4-turn to
release the Cover from the mounting brackets (see Figure 10-8). Remove the Cover from the
dispensing chamber.
7. Disassemble the Dispensing Calibration Module as follows (see Figure 10-9):
a. Remove the Weigh Station Cover.
b. Remove and discard the Weigh Station plastic cup.
c. Carefully remove the Scale Pedestal from inside the Breeze Shield.
d. Carefully remove the Breeze Shield by lifting it straight out of the Weigh Station.
e. Remove the three 4-mm socket head cap screws attaching the Dispensing Calibration
Module to its mounting bracket.
f. Disconnect the Needle Sensor Cable and Purge Station Vacuum Hose from the
Dispensing Calibration Module.
g. Remove the Dispensing Calibration Module from the dispensing chamber.
1
2
3