Installation Manual

10-18 Parts Replacement
d. Carefully remove the Scale Control Module from the Rear Cabinet.
? NOTE Return the Scale Control Module to Asymtek even if it is not a failed unit. Refer
to “Return Material Authorization” in this section for merchandise return
instructions.
Item Description
1 Mounting Screws
2 Interconnect Cable
3 Communication Cable
4 Power Cable
5 Scale Control Module
6 Floor of Rear Cabinet
Figure 10-7 Removing/Installing the Scale Control Module
5. Open the Front Hatch and manually move the Dispensing Head toward the back of the
dispensing chamber.
WARNING! Avoid contact with Heater Tooling or Needle Heaters. These heated elements will
stay hot after shutdown and may cause serious burn injury.
4
2
3
1
5
6