Installation Manual

10-8 Parts Replacement
Panel Mounted Fuses
These glass fuses are located on the front panel of the Conveyor Controller. The fuses protect the
Controller from damage caused by power surges from the Heater Tooling. See Figure 10-2.
CAUTION! Always replace fuses with fuses of identical rating and size. Failure to do so may
not protect components from damage.
To remove and replace panel mounted fuses:
CAUTION! This procedure should only be performed by a trained service technician.
1. Perform a Service Shutdown as specified in the Safety section of this manual.
2. With your fingers, gently push in and turn the Fuse Holder counterclockwise until the head of
the Fuse Holder pops out enough to allow you to grasp it. See Figure 10-2.
3. Pull the Fuse Holder out of its socket.
4. Remove and discard the damaged fuse.
5. Verify that you will be installing the correct replacement fuse and then insert the new fuse
into the Fuse Holder.
6. With your fingers, simultaneously push and twist the Fuse Holder clockwise into the socket
until it locks into place.
7. Perform a Post-Service Start-up as specified in the Safety section of this manual.