Installation Manual
Parts Replacement 10-5
Replacing Fuses
Use the following procedures to remove and replace a fuse if fault isolation procedures in the
Troubleshooting section of this manual have confirmed that it must be replaced.
CAUTION! Always replace fuses with fuses of identical rating and size. Failure to do so may
not protect components from damage.
Tools and Materials Needed
• ESD Grounding Strap • Replacement Fuse (see Table 10-1)
• Small Flat Head Screwdriver
Fuse Mounting
This subsection describes the replacement of glass fuses mounted in the following manner:
• Board Mounted Fuses
• Panel Mounted Fuses
• Box Mounted Fuses
Replacement Fuses
There can be up to 14 replaceable fuses (see Table 10-1) on Axiom X-1000 Series Dispensing Systems
depending on the configuration of your system. All fuse locations are clearly labeled.
Table 10-1 Replaceable Fuses
Part
Number
Qty. Location Rating Size Mount
Type
55-5635 1 Conveyor Controller Power Supply 5A, 250V, Slow 0.25 x 1.25 in. Board
55-5322 1 Main Interface PWA 2A, 250V, Fast 5 x 20 mm Board
194018 1 Main Interface PWA 5A, 250V, Fast 5 x 20 mm Board
194023 2* Servo Supply Transformer Power Inlet 8A, 250V, Fast 5 x 20 mm Box
194023 8 Front of Conveyor Controller 8A, 250V, Fast 5 x 20 mm Panel
195967 1 Main Interface PWA 0.25A, 250V, Slow 5 x 20 mm Board
* One of the fuses in the drawer is a spare.